Sign In | Join Free | My fazendomedia.com
fazendomedia.com
LABOTRIX GROUP LIMITED
LABOTRIX GROUP LIMITED FOR EDUCATION, FOR THE FUTURE
Home > Data Logger Sensors >

Multi Channel Data Logger Sensors With Data Logger For Temperature Measurement ,

Multi Channel Data Logger Sensors With Data Logger For Temperature Measurement ,

Place of Origin : China
Brand Name : LABWE
Certification : ISO 9001, CE, FCC, ISO14001 (environment certificate), RoHS
Model Number : LBD001
MOQ : 5 Sets
Packaging Details : CARTONS ( wooden can be available if in special amount and requirement)
Delivery Time : 25 days after payment
Payment Terms : T/T
Supply Ability : 10000 Sets/Month
Function : data discovery|data transmitting|Laboratory data acquisition
Appearance : LCD display|non-display
Measurement : Atmospheric Pressure|Carbon Dioxide|Distance|Force|Humidity|Oxygen|Temperature
Application : indoor and outdoor
Contact Now

Multi Channel Data Logger Sensors With Data Logger For Temperature Measurement , OEM


datalogger & sensor,digital lab sensor,temperature sensor,educational sensor,school sensor,temp sensor,pressure sensor,motion sensor,oxygen sensor,light sensor, wireless sensor,datalogger,data logger

function:Laboratory data acquisition, data discovery, data transmitting


appearance:LCD display, non-display

measurement:Temperature, Humidity, Carbon Dioxide, Oxygen, Distance, Atmospheric Pressure, Force


Quick Description:

Laboratory Datalogger with Screen
Multi-channel data acquisition
Independent research
Sensitive inductor
OEM service


Description:

A full set of independent device specially designed to assist both teachers and students to demonstrate or analyze the experiment process in a direct manner. This device is applicable to both indoor and outdoor experiments with PC connections via Bluetooth or data cable.
The complete set of device consists of a data logger powered by Microsoft WIN CE 5.0 and 26 sensors, each measures a specific changeable parameter(sound, temperature, electric current, force, voltage etc.).
Customers are free to choose among or the entire set of functions upon purchase, to cater for their own needs.


Specifications:


NO.

Product Name

Model NO.

Specifications

PHYSICS

1

Temperature Sensor

TEM-1201

The temperature sensor is designed to measure the change in

temperature

of solids, gases and liquids with the following features:
- Temperature range: -20 ° C to +120 ° C
- Measurement error: not more than 0.01 ° C
- Resolution: not less than 0.05 ° C
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

2

Sound Sensor (Acoustic sensor )

SS-1203

The sensor is designed to measure the change in amplitude(force) of

sound

with the following features:
- Amplitude range from 40 to 110 dBA
- Resolution: not less than 0.01 dBA.
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

3

Light Intensity Sensor

LIS-1204

The sensor is designed to measure the change in intensity of

light with the

following features:

- Resolution: not less than 2 lux(0 to 600lux)

- Resolution: not less than 5 lux(0 to 13000lux)
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

4

Atmospheric pressure sensor

ATP-1228

The sensor is designed to measure the change in atmospheric

pressure

with the following features:
- Pressure range: 0 to 700 kPa;

- Measurement error: no more than 0.3 kPa;
- Resolution: not less than 0.5 kPa.
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

5

Force Sensor

FS-1207

The sensor is designed to measure the change in force with the

following

features:

- Measurement range: -50 N to +50 N

- Resolution: not less than 0.1 N
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

6

Magnetic field sensor

MFS-1208

The sensor is designed to measure the change in magnetic field density

with the following features:
- Measurement range: -64 mTesla to +64 mTesla
-Measurement error: not more than 0.05 mTesla

- Resolution: not less than 0.01 mTesla

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

7

Distance Sensor (Motion sensor)

DS-1212

The sensor is designed to measure the change in distance of an

object

with the following features:
- Measurement range: 20 cm to 200 cm

-Measurement error: not more than 2%

- Resolution: not less than 1 mm

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

8

Acceleration sensor

ACL-1229

It is designed to measure the change in acceleration of a moving

object with

the following features:
- Measurement range: -6 g to +6 g

-Measurement error: not more than ±0.01g
- Resolution: not less than 0.0005 g±0.01g

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

9

Voltage sensor

VS-1206

The sensor is designed to measure the change in voltage of the AC

and DC

with the following features:

- Measurement range: -25 V to +25 V
- Resolution: not more than 10 mV
- Intrinsic resistance: not less than 2 MΩ

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

10

Current Sensor

CS-1210

The sensor is designed to measure the change in current with the

following

features:

- Measurement range: -1 A to +1 A
- Resolution: not more than10 mV
- Intrinsic resistance: not less than 0.2 MΩ

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

11

Photoelectric sensor

PE-1218

It is designed to measure the change in photoelectric current with the

following

features:
- Measurement range: 1 μs to 99 s

- Accuracy: not more than ±2%

- Resolution: not less than 1 μs

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

CHEMISTRY

1

Temperature Sensor

TEM-1201

The temperature sensor is designed to measure the change in

temperature

of solids, gases and liquids with the following features:
- Temperature range: -20 ° C to +120 ° C
- Measurement error: not more than 0.01 ° C
- Resolution: not less than 0.05 ° C
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

2

PH sensor

PH-1211

The sensor is designed measure the change in pH level of chemical

solvents

with the following features:
- Measurement range: 0 to 14

- Accuracy: not more than 0.01
-Resolution: not less than 0.01
.The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

3

Voltage sensor

VS-1206

The sensor is designed to measure the change in voltage of the AC

and DC

with the following features:

- Measurement range: -25 V to +25 V
- Resolution: not more than 10 mV
- Intrinsic resistance: not less than 2 MΩ

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

4

Current Sensor

CS-1210

The sensor is designed to measure the change in current with the

following

features:

- Measurement range: -1 A to +1 A
- Resolution: not more than10 mV
- Intrinsic resistance: not less than 0.2 MΩ

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

5

CO2 sensor

C02-1215

It is designed to measure the change in carbon dioxide level in the air

with the

following features:
- It contains NASICON type solid electrolyte (or its equivalent) as its

sensory

element;
- Measurement range: 0 ppm to 10,000 ppm
- Resolution: not less than 10 ppm

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

6

O2 sensor

O2-1214

It is designed to measure the chang in oxygen level in the air with the

following

features:
- Measurement range: 0% to 100%

- Accuracy:not more than 0.2%
- Resolution: not less than 0.1%

The sensor has a data logger connection, a mounting hole for

conveniency during experiment as well as an auto-detection function for accurate

calibration

7

Atmospheric pressure sensor

ATP-1228

The sensor is designed to measure the change in atmospheric

pressure with

the following features:
- Pressure range: 0 to 700 kPa;
- Measurement error: no more than 0.3 kPa;
- Resolution: not less than 0.5 kPa.
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

BIOLOGY

1

Temperature Sensor

TEM-1201

The temperature sensor is designed to measure the change in temperature

of solids, gases and liquids with the following features:
- Temperature range: -20 ° C to +120 ° C
- Measurement error: not more than 0.01 ° C
- Resolution: not less than 0.05 ° C
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

2

pH sensor

PH-1211

The sensor is designed measure the change in pH level of chemical

solvents

with the following features:
- Measurement range: 0 to 14

- Accuracy: not more than 0.01
-Resolution: not less than 0.01
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

3

ECG harness

ECG-1209

The sensor is designed to measure the change in voltage generated by

depolarization of the heart muscle, with the following features:
- It includes a set of ECG- electrode plates allowing the attachment to the

human body, with connection wires. A minimum of 6 electrode plates are

needed
- Measurement range: -5 mV to +5 mV


The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

4

Respiratory rate sensor

RRS-1213

It is designed to measure the chang in the rate of respiration in the

human body:

- Measurement range: 0 l/min to 315 l/min
- Resolution: not less than 0.05 l/min

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

5

CO2 sensor

CO2-1215

It is designed to measure the change in carbon dioxide level in the air

with

the

following features:
- It contains NASICON type solid electrolyte (or its equivalent) as its

sensory

element;
- Measurement range: 0 ppm to 10,000 ppm
- Resolution: not less than 10 ppm

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

6

O2 sensor

O2-1214

It is designed to measure the chang in oxygen level in the ai with the

following

features:
- Measurement range: 0% to 100%

- Accuracy:not more than 0.2%
- Resolution: not less than 0.1%

The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

7

Humidity sensor

HS-1202

The sensor is designed to measure the change in humidity with the

following

features:
- Measuring range: 0 to 100%
- Measurement error: no more than ± 2%
- Resolution: not less than 0.1%
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration

8

Light Intensity sensor

LIS-1204

The sensor is designed to measure the change in intensity of light with the

following features:

- Resolution: not less than 2 lux(0 to 600lux)

- Resolution: not less than 5 lux(0 to 13000lux)
The sensor has a data logger connection, a mounting hole for

conveniency

during experiment as well as an auto-detection function for accurate

calibration


Competitive Advantage:

1, Microsoft WIN CE 5.0 operating system.
2, Simple, intuitive and convenient interface.
3, Compatible sensor input terminals.
4, Interactive multimedia teaching resources.
5, Powerful graphical processor:
Able to process and display different graphical interfaces and data tables.
Able to process and display multiple curves simultaneously with free selection of curve colors.
Auto adjustment of axis scales based on the actual curve to facilitate better observation.
6, Equipped with Function Input technology such as Derivative, Indices, Logarithmic, Fourier, Trigonometric functions and so on.
7, Able to indicate each and every X , Y coordinates as well as gradients corresponding to any two points along the curve.
8, Multilingual technology and language conversion in accordance with customer demand.
9, Built-in calculator to establish mathematical models or data.
10, Able to enter or edit registered data.
11, Multi-sensor accessing available.
12, Manual or auto saving/extracting of experimental data available.
13, Automatic activation of sensors without driver.
14, Supports multimedia play function.



Product Tags:

data logging sensors

      

portable Data Logger

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Multi Channel Data Logger Sensors With Data Logger For Temperature Measurement , Images

Inquiry Cart 0
Send your message to this supplier
 
From:
To: LABOTRIX GROUP LIMITED
Subject:
Message:
Characters Remaining: (0/3000)